ATEX Zero-Gravity Tool Balancer TECNA 9508AX (176 to 198 lb, 6.9ft)
$1,764.83
Add to Cart- Availability: In Stock
- SKU: : 9508AX
- Type:: Explosion Balancers
- Brand:: TECNA
Description
The TECNA 9508AX is an ATEX-certified zero-gravity tool balancer for tools weighing 176-198 lb. Zero-gravity means the load stays wherever you leave it instead of returning to a rest position - let go at mid-height and the tool simply hangs there, weightless to the operator.
Cable travel is 6.9 ft (2,100 mm) and capacity is adjustable across 176-198 lb (80-90 kg) by worm screw. It carries two markings: II 2G Ex h IIA T6 Gb for gas, and II 2D Ex h IIIC T85°C Db for dust.
This balancer is rated for combustible dust as well as flammable gas. The dust marking covers Zone 21 and Zone 22, and group IIIC - the widest dust group, taking in conductive dusts as well as non-conductive dusts and combustible fibres. T85°C is the maximum surface temperature, so it can be used where dust deposits have an ignition or smouldering temperature above 85°C.
What the two markings mean:
II - for surface industry, not mining
2G / 2D - category 2. Zone 1 and Zone 2 for gas, Zone 21 and Zone 22 for dust
Ex h - protection by constructional safety, to EN ISO 80079-37 for non-electrical equipment
IIA / IIIC - the gas group and the dust group. Group IIA covers propane, butane, methane, acetone, ammonia, gasoline, toluene, xylene, methanol and iso-propyl alcohol among others. It does not cover ethylene, di-ethyl ether, acetylene or hydrogen.
T6 / T85°C - temperature class for gas, maximum surface temperature for dust
Gb / Db - equipment protection level: no effective ignition source in normal operation or expected malfunction
It comes with a manual lock, so you can lock the load in place when you need to - push and turn the pin 90 degrees to hold it, turn it back to release. Only operate the lock with the load hanging.
A friction brake device is available as option F, which controls the speed of drum rotation. It cannot be retrofitted - it has to be specified when the balancer is ordered, so if you want it, order the TECNA 9508.FAX instead of this model.
The balancer must be grounded at installation.
The balancer is intended to be used indoors, at 41 to 140 F (5 to 60 C). Outside that range there will be premature deterioration of the unit or its components. If it will meet chemically aggressive gas, liquid or powder, confirm compatibility with us before ordering.
Four things that are easy to get wrong:
The tool you hang on it must itself be ATEX certified to a hazard class equal to or higher than the balancer. An ATEX balancer does not make a non-ATEX tool acceptable
Static electricity carried on people can be an ignition source. Ground every conductive object, not just the balancer
Do not let the snap hook strike other metal nearby. That can throw a mechanical spark
Do not use the balancer if it is visibly damaged. Unintended friction is an ignition risk in its own right
Specifications:
Capacity: 176-198 lb (80-90 kg), adjustable by worm screw
Cable travel: 6.9 ft (2,100 mm)
ATEX marking, gas: II 2G Ex h IIA T6 Gb
ATEX marking, dust: II 2D Ex h IIIC T85°C Db
Ambient temperature: 41 to 140 F (5 to 60 C)
Unit weight: 35.71 lb (16.20 kg)
Stainless steel cable
Ribbed and sealed aluminium alloy construction
Entirely conductive, grounded, spark-proof materials
Locking device to hold the load at any height
Safety suspension, and upper rotary suspension with safety hook
Safety device against load dropping due to spring breakage
Taper drum rotating on ball bearings
Rotary upper hook with ball bearing
Adjustable stroke limiting device
Cable guide in antifriction material
Inert spring drum assembly
Options:
RC (7270000004) - conductive rotary hook group. It lets the tool turn freely without twisting the cable, while keeping the hook conductive rather than breaking the path a plain swivel would. Rated to 200 kg, and can be fitted at any time
BC (7190000004) - a locking and unlocking device operated from floor level. The balancer already has a manual lock on the unit itself; this puts the control within reach at ground level, so you can lock and release the load without going up to the balancer
F - the brake device described above. New order only
The structure you hang it from has to be stronger than five times the balancer weight plus the maximum load - and if several balancers share one structure, five times the total of all of them, each on its own independent connection point. And at every service, check the ground cable and the tightness of that marked screw, and clear away dust - no more than 5 mm of buildup.
Every production lot is sample-tested: a static test at 1.25 times the maximum rated load held for ten minutes at full stroke, to DIN 15112, and a dynamic test at 1.1 times maximum load run for an hour.